75% SAL-F
$228.66
Disposable unsaturated (0.753 aw) salt saturated slurry
Description
Water activity standards are used to check the performance and calibration of water activity instruments. These standards have specific known water activity values that cover the entire water activity range. There are two main types of water activity standards, saturated salt slurries, and unsaturated salt solutions. Either standard can be used to verify and calibrate water activity instruments and as would be expected both standard options have advantages and disadvantages.
The advantage of saturated slurry standards is that they can be reused for up to three years, if maintained properly, and are easily prepared without a precision balance and complicated recipes. Their disadvantage is that they take longer to equilibrate and are temperature sensitive.
The advantage of unsaturated salt standards is that they can be made to any water activity value, are faster to equilibrate and are less temperature sensitive. The disadvantage of unsaturated standards is that they are single-use only and must be purchased as a consumable.
The availability of both standards ultimatelyallows the user to choose the standard type that best fulfills their needs. Novasina is the only water activity provider that provides both types of standards: saturated salt slurry standards called SAL-T and unsaturated salt solution standards called SAL-F.
Saturated Salt Slurry Standards (SAL-T)
| Pros | Cons |
| Reusable with up to 3 years of shelf life | Slow to equilibrate |
| Easy to Use | Temperature Sensitive |
| Long term savings | Water activity value limited by the type of salts |
Unsaturated Salt Solution Standards (SAL-F)
| Pros | Cons |
| Fast to equilibrate | Single Use Only |
| Less Temperature Sensitivity | Must be prepared to correct concentration |
| Allows for fast qualification and verification | Must be purchased as a consumable |
To use these unsaturated salt slurries for fasterst possbile calibration or verification you will need to use the SAL-F starter kit and SAL-F pads.
| Humidity Value | Part Number | Name | LabStart-aw Calibration | LabSwift-aw Calibration | LabTouch-aw Calibration | LabMaster-aw NEO Calibration | Verification |
| 11% | NV2602086 | SAL-F 11 | ✔ | ✔ | ✔ | ✔ | |
| 33% | NV2602087 | SAL-F 33 | ✔ | ✔ | ✔ | ✔ | ✔ |
| 58% | NV2602088 | SAL-F 58 | ✔ | ✔ | ✔ | ✔ | |
| 75% | NV2602089 | SAL-F 75 | ✔ | ✔ | ✔ | ✔ | ✔ |
| 84% | NV2602090 | SAL-F 84 | ✔ | ✔ | ✔ | ✔ | |
| 90% | NV2602091 | SAL-F 90 | ✔ | ✔ | ✔ | ✔ | |
| 97% | NV2602092 | SAL-F 97 | ✔ | ✔ | ✔ |