Eddy Jet 2- Spiral Plater

The Best Spiral Plater just got Better! Quicker, Quieter and more Robust!

Our Price:
Manufacturer: IUL S.A.
SKU: 90003700

The all new Eddy Jet 2 Spiral Plating System is a color screen touch screen fully programmable spiral inoculation instrument with accuracy and reproducibility of greater than 99%. The Eddy Jet 2 Spiral Plater uses a unique gamma-Irradiated disposable micro-syringe for each new sample, eliminating cross-contamination and the need for a vacuum source or washing steps.

Since the samples come in contact only with the disposable low cost micro-syringe throughout the process, there is absolutely no risk of carryover of sanitizing chemicals, such as hypochlorite.

The tips are supplied with fully traceable quality control documentation. These sterile, precise micro-syringes (with opening size of 0.7mm) are your keys to confidence that you’ll get an accurate inoculation and no contamination on every plate that you process with the Eddy Jet 2 Spiral Plater.

Significant savings can be made in material costs and workers' time by using the Eddy Jet 2 Spiral Plater. Plates are processed in well under 1 minute; no time consuming washing cycle; no time consuming preparation and replacement of washing chemical solutions; no time consuming maintenance of a vacuum pumping system; no down time due to vacuum failure.

For Spiral Plating official method as stated by the FDA Bacteriological Analytical Manual (BAM) click here

Check how Spiral plates can be count using Manual colony counter or automatic colony counter.

YES:

  • Highest precision & Accuracy
  • High confidence in results
  • Programmable
  • Very dependable
  • Preprogrammed modes
  • Extremely easy to use

NO:

  • Wash cycles
  • Concerns about carryover
  • Chemical/bleach solutions
  • Noisy vacuum pump
  • Vacuum failure down time

Compare our Eddy Jet 2 to other Spiral platers

  Eddy jet 2 Others
Disposable Irradiated syringe X
No Nozzle that tend to jam X
No risk of cross-contamination X
No need to prepare fresh bleach / water solution each day X
No risk of false results X
No use of Bleach Ethanol for the wash cycles X
No Noisy vacuum pump X
Reproducibility / Accuracy ±1% ?

Features and Benefits

No use of bleach
Disposable syringes will prevent cross contamination
No "Down Time" due to washing of the tip (disposable)
Increases lab productivity by applying automation
Innovative touch screen with intuitive icon operation
Ease of use and programming
Reliable and robust design for years of operation
Knowledgeable application support programs
Bar Code, Network compatibility
IUL Instruments leadership position backed by 20 years of experience and excellent reputation

Technical data

Maximum Syringe Volume 100 µl
Maximum Flow Rate 50 µl / sec.
Minimum Step Volume < 0.1 µl
Reproducibility < 1%
Spreading Modes Stored all the accepted
External Balance Connection serial RS232
Printer Connection serial RS232 by IUL
Mains 230/100 VAC, 50/60 Hz.
Power 440W
Dimensions (WxHxD) 19.7" x 12.6" x 16"
Weight 44 lb.

Ordering Info

Eddy Jet. Complete with 1000 syringes and 1000 sample cups. CAT. NO. 1700 (220VAC)
CAT. NO. 1701 (110VAC)

Ordering Info Disposables

Syringes. Pack of 1000 in boxes of 10 for the use with the automatic feeder. CAT. NO. 1780
Cups. Pack of 1000 disposable. CAT. NO. 1790
Syringes and cups are irradiated with gamma-rays

View video

Download Center

EddyJet Info

Download Center

EddyJet Spreading Modes

  • Eddy Jet 2- Spiral Plater
    4

    We recently switched from another brand of spiral plater to the Eddy Jet. While doing our correlation study we ran both units simultaneously and quickly noticed that we were starting the 3rd sample on the Eddy Jet while the 1st sample finished on the other brand. With our sample volume, this equates to a significant time savings
  • Eddy Jet 2- Spiral Plater
    4

    The Eddy Jet is the most user friendly Spiral Plater I have ever used. Unlike other units, we don ' t need to think twice before operating it. The disposable syringes and not having a vacuum pump are great plus for us. We like its functionality very much.
  • Eddy Jet 2- Spiral Plater
    5

    We have recently purchased our 2nd Eddy-Jet after 10 years of an Eddy-Jet Spiral plater working at our lab. As a 7 year Eddy-Jet user myself, the time savings we get as a result of the 3 fold dilution and the reliability of the unit are the major benefits for us
  • Eddy Jet 2- Spiral Plater
    5

    We had it up and running within an hour of delivery. It arrived with several clinical samples, all of which were plated on the new machine. Everything was fairly intuitive even without reading any directions! We have used every day since. It takes about the same length of time as our old machine, but is much simpler and more fool proof even for complete novices (new students in the lab).

1-888-810-5179