tempmaxx_precision_measurement_for_detection_of_temperature_12
tempmaxx_precision_measurement_for_detection_of_temperature_2
tempmaxx_precision_measurement_for_detection_of_temperature_5
tempmaxx_precision_measurement_for_detection_of_temperature_4
tempmaxx_precision_measurement_for_detection_of_temperature_6

TempMaxx

Temp Maxx
Transmitter for temperature measurement in the HVAC industry

Manufacturer: Novasina
SKU: 2600284

TempMaxx

Transmitter for temperature measurement in the HVAC industry

The TempMaxx is a precision measurement instrument with integrated control functions for the detection of temperature with external probes.

The big and clear displays, intuitive menu structure as well as the possibility to connect various sensors make this device extremely versatile for almost all industrial applications. 

This instrument provides a scalable analogue output (U & I) as well as a relay switch output for 2 point control functions. The large LCD display indicates temperatures up to +400°C and °F.

All versions of PT 100 / 1'000, Ni 1'000 or NTC elements can be connected in 2-, 3- or 4-wire technology.

 

Range of use

Using the integrated adjustment function, the TempMaxx transducer can be adapted ideally to each external temperature sensor.

 

Additional functions

Limit value generation for alarming and use as 2-point controller. The necessary relay digital output is available.

All parameters are set via the intuitive menu navigation with password protection.

 

Features and Benefits

  • Highly flexible, capable to connect  PT/ Ni / NTC probes
  • Big, clear LCD display
  • Easy calibration capability
  • Robust design
  • Intuitive menu structure
  • Easy mounting and start-up

Applications

  • HVAC process-control and monitoring
  • Production processes in paper- & textile industry
  • Control of heating coils
  • Archives, libraries, museums, storage
  • Apparatuses, climatic chambers, controls
  • Storage systems, cooling rooms

Measuruement data

 Outputs  
 Analogue OUT::

 1 x U and I

0 or 2...10V DC

0 or 4...20 mA DC

 Digital OUT:

1 Relay-switch NO, NC

max. 260VAC / 2A (ohmic load)

   
 Temperature measurement 2-, 3-, or 4-wire
Sensor connection:  
 Sensor types:

 PT 100 DIN 60751 / PT 1'000/Ni 1'000

/ AA / A / B / 1/3B / C NTC type "Beta-Therm"

   

Connection PT /Ni / NTC probes 

Resistor temperature sensors DIN EN 60751 

PT 100  (0,4 Ohm/K) -50 ... +400°C

Connection 2-, 3- or 4-wire technology

Tolerance class 1/3 B, A, B

PT 1000  (4,0 Ohm/K) -50 ... +400°C

Connection 2-, 3- or 4-wire technology

Tolerance class 1/3 B, A, B

 

Resistor temperature elements DIN 43760

Ni 1000  (5,5 Ohm/K) -50 ... +200°C

Connection 2-, 3- or 4-wire technology

Tolerance class 1/3 B, A, B

NTC Beta Therm (30 kOhm) -20...°80°C

Connection 2-wire technology

Tolerance class +/- 0.15K

Voltage supply 24VDC, output ranges can be scaled individually

Setting options 4-20mA, 0-20mA, 2-10V, 0-10V = 0-100% und -20-80°C 

 

Download Center

Data Sheet

1-888-810-5179

Email us

Get In Touch

Flicker