To begin, it is important to understand that the terms Autoclave and Sterilizer are interchangeable. Autoclave devices are primarily used in laboratories, while sterilizers are more commonly used for medical and pharmaceutical applications. When used by researchers studying food production, a food preservation autoclave machine uses steam to kill harmful bacteria, viruses, fungi, and spores that may be present on subject matter that is placed inside the pressure vessel. The subject matter is then heated to an appropriate sterilization temperature for a given amount of time. During this period, moisture in the steam will efficiently transfer heat to the subject matter to effectively destroy the protein structure of any bacteria and/or spores that may be present.

There are three factors that must be present to ensure a successful autoclave food preservation process. These are time, temperature and steam quality.  Meeting these requirements involves three phases in the food autoclave process:

  1. Conditioning Phase: Air inhibits the food autoclave process and must be removed from the chamber during the first phase of the sterilization cycle. This cycle is known as conditioning. In dynamic air removal-type steam sterilizers, the air can be removed from the chamber using a vacuum system. It can also be removed without a vacuum system using a series of steam flushes and pressure pulses. Gravity-type sterilizers use steam to displace the air in the chamber and force the air down the sterilizer drain.
  2. Exposure Phase: Next, the food autoclave drain will close, to allow steam to be continuously admitted into the chamber, thereby rapidly increasing the pressure and temperature inside to a predetermined level. The cycle then enters the exposure phase, where subject items are held at the sterilization temperature for a fixed amount of time required to sterilize them.
  3. Exhaust Phase: During the final phase of the cycle, exhaust, the sterilizer drain is opened and steam is allowed to escape, thereby depressurizing the vessel to allow the items in the load/batch to dry.

NOTE: The steam quality is vital to a successful food preservation autoclave process. The steam used for sterilization should be composed of 97% steam (vapor) and 3% moisture (liquid water). This ratio is recommended for the most efficient heat transfer. When the steam moisture content is less than 3%, the steam is described as superheated (or dry). Superheated steam is too dry for efficient heat transfer and is ineffective for successful autoclave food preservation processes. 

Neutec recommends the Vertical Autoclave by Raypa, an optimal food preservation autoclave machine. Details of this product follow:

Retorts with counter pressure

Both pasteurization and sterilization are techniques of autoclave food preservation by applying heat. Their aim is the destruction of microorganisms and their spores. The difference between the two techniques lies in the time and temperature of the heating process.

Sterilization

Sterilization is performed on a variety of foods, such as meat, fish, vegetables, and fruit.  It is performed by placing food in a container and subjecting it to temperatures above 100ºC, usually 121ºC, during a certain period of time. After this process, all microorganisms and spores are inactivated.

Pasteurization

Pasteurization involves heating food at temperatures below 100ºC for a brief period of time. This method is used in many products, especially in milk and its derivatives, flavored juices, beers, because the low temperatures respect and preserve the aromas and other organoleptic characteristics. These food products have a shorter shelf life, because although viable microorganisms are drastically reduced, some remain viable.

Model CFS-28VCFS-50VCFS-75VCFS-110VCFS-150V
 Capacity33L55L79L115L175L
 Chamber Dimensions 300 x 420 mm300 x 690 mm400 x 580 mm400 x 830 mm500 x 760 mm
 Chamber Volume total/usable 33/30L 55/48L79/73L115/104L175/150L 
 External Dimensions LxDxH505 x 580 x 1110 mm 505 x 580x 1290 mm610 x 700 x 1185 mm610 x 700 x 1435 mm750 x 820 x 1400 mm
 Weight90 kg110 kg140 kg180 kg265 kg
 Power3200 W3200 W6000 W6000 W9000 W
 Frequency 50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz
 Electrical Voltage * 230 (1P+N+E) V  230 (1P+N+E) V400 (3P+N+E) V  400 (3P+N+E) V400 (3P+N+E) V 
 Amperage14.5 A14.5 A9 A 9 A14 A
* Ask for other voltages

Safety Features

  • Protection against overpressure in the chamber
  • Safety thermostat
  • Open door detection
  • Positive pressure detection in the sterilization chamber
  • Water inlet pressure sensor
  • Water level detector
  • Cover thermal protection of the lid
  • Protective chassis for the sterilization chamber

Specifications

Temperature50-130ºC
Sterilization Time1-250 minutes
Max Pressure2.2 bar
Programmable Counterpressionup to 2.2 bar, depending on selected temperature
Double System Temperature ControlPT100 Flexible probe and Fixed probe in the sterilization chamber
Sterilization Control Systemby programming the F0 value and maximum temperature
Pasteurization Control Systemby programming the P0 value and maximum temperature  
Chamber and Lid MaterialAISI 316L stainless steel
External Case MaterialAISI 304 stainless steel
GasketSilicone rubber
Connection PCEthernet port
USBAutomatic export of results to USB key
Storing of Test Cycles100 sterilizations cycles
Number of Programs50 programs
Programmable AutostartDate and time
Automatic Water FeedingMinimum water inlet pressure 3.5 bar
Screen5″ color touch screen
Cooling SystemDirect shower in sterilization chamber
Casters4 wheels, 2 of them with brake

Download Center

Food Preservation Autoclaves Technical Information
Food Preservation Autoclaves Brochure

View Video

Retort | Autoclave for preserved food | Food sterilizers of 33-175L | TERRA Food-Tech®
I. S am p l e p r e p a r a t i o n II. A g ar p r e p a r a t i o n a n d p o u r i n g A g ar/ M e d i a S t e r i li z a t i o n/ P r e p a r a t i o n XY (Z) T u b e & B o tt l e F i l l e r A g ar/ M e d i a F i ll i n g/ P o u r i n g A g ar P l a t e s S am p l e H o m o g e niz i n g S am p l e D i lu t i o n Y o ur S am p l e III. S p i r a l p l a t i n g C o l o n y C o un t i n g I V . A u t o m a t e d c o l o n y c o un t i n g R e s u l t s S am p l e I n o c u l a t i o n